Free electrical foundations guide

Reading electrical drawings: follow tags, legends and revisions

A symbol is a starting point. To understand a fictional drawing, connect its tag to its legend, schedule and applicable revision. Keep a short evidence trail so another reader can follow your answer.

Read the information around the picture

Before interpreting a tag, identify the drawing and its revision information. Read the local legend instead of assuming a shape has the same meaning everywhere. A schedule may supply details that would make the main picture too crowded. Notes and revision references can change how a particular tag should be read.

For this exercise, use a simple trail: device ID → applicable revision → type → schedule entry. That order follows the specific rules below. It is not a universal rule about which document wins in a real project.

Worked example: keep identity and type separate

This invented mini-plan has three tags: P1/L, P2/L and P3/N. The part before the slash is the unique device ID. The letter after it is a type. A revision marker applies only to P2 and changes its type to M. The exercise explicitly says that this revision replaces P2’s original type only.

Fictional type schedule, used only in this exercise
TypeListed power
L14 W
M9 W
N7 W
  1. P1: no applicable revision, so its type remains L. Look up 14 W.
  2. P2: follow its revision to type M. Look up 9 W. Its ID stays P2.
  3. P3: no applicable revision, so its type remains N. Look up 7 W.
  4. Total the listed values: 14 + 9 + 7 = 30 W.

Ignoring the revision would produce 35 W. Applying the revision to both type-L devices would produce 25 W. Both errors come from reading the revision’s scope incorrectly. Neither total tells you whether any real installation is adequate.

Try the same reading method on a picture

Fictional plan with tags H1/B, H2/C, H3/B and H4/A. A triangle R beside H3 points to a revision changing H3 to type C. Type A is Pendant 12 W, B is Linear 24 W and C is Round 18 W.
VirtualWorks’ original public demo drawing. Its legend applies only to this drawing. The text equivalent below contains the same information.
Text equivalent of the public drawing

The upper tags are H1/B and H2/C. The lower tags are H3/B and H4/A. Only H3 has a triangle R. The legend says that triangle R means to replace that device’s plan type with the revision-table type. The revision table says H3 uses type C. The schedule lists A: Pendant, 12 W; B: Linear, 24 W; C: Round, 18 W. Other device tags remain unchanged.

Common mistakes and corrections

Explain it back

In the mini-plan, why is P1 still 14 W after P2 changes to type M? A useful explanation names the revision’s scope, not just the final total.

Source and scope

For general background on title blocks, revisions, notes and legends, see the U.S. Department of Energy’s Engineering Symbology, Prints, and Drawings, Volume 1, Module 1 (1993). The mini-plan, its hierarchy and its numbers are original givens, not claims about a drawing standard. The linked public SVG is original VirtualWorks artwork.